Dissolved oxygen meter SevenExcellence S900
The model S900 offers a bench-top solution with OptiOxÀ technology: the optical measurement of dissolved oxygen. Thanks to OptiOxÀ, measuring dissolved oxygen is easier than ever before. For applications where the traditional polarographic measurement is preferred the S600-Kit is recommended. Optical oxygen measurement is superior to conventional technologies. OptiOxÀ is fast, precise and produces highly reproducible results. Because of the optical measuring principle used, the oxygen is not chemically consumed during the measurement, which makes stirring the sample superfluous. The InLab OptiOxÀ requires no polarization time, meaning you can start your measurement immediately. In addition, the whole measuring system has a high level of stability making calibration rarely necessary.
Supplied with:
S900-Kit:As S900-Basic but with InLabÂź OptiOx, guide to DO measurement and zero oxygen tablets.
Other types: S900-Basic: Includes instrument, DO/BOD expansion unit, 2 blank expansion units, uPlace electrode holder, semitransparent cover, operating instructions, installation and quick guide, LabXÂź direct pH PC software, declaration of conformity and test certificate.
Specifications
Measuring range (O2 Saturation)
InLabÂź OptiOx: 0.0 to 500 %
Resolution: 0.1
Measuring range (O2 concentration):
InLabÂź OptiOx: 0.000 to 50 mg/l (ppm)
Resolution: 0.001/0.01/0.1
Accuracy
InLabŸ OptiOx: ±0.1 mg/l from 0 to 8
±0.2 mg/l from 8 to 20
±10 % from 20 to 50
Measuring range (Pressure): 500 to 1100 mbar
Resolution: 1
Accuracy: ±2
Calibration points: 2
Sensor input:
InLabÂź OptiOx: MiniLTW (IP67)
Pressure compensation: automatic / manual
Type S900-Kit
Specifikationer
- FrÄgor om produkten, vÀnligen kontakta
- Jörgen Mattson, jm@buch-holm.se, +46 (0)40 305030
- Producent
- Mettler-Toledo
- Förpackning
- 1 st.
- Enhet i försÀljning
- EA
- UNSPSC
- 41115611 Udstyr til mÄling af oplÞst ilt
SyrgasmÀtare DO, Mettler-Toledo SevenExcellence S900-Kit, m. elektrod
Beskrivning
Dissolved oxygen meter SevenExcellence S900
The model S900 offers a bench-top solution with OptiOxÀ technology: the optical measurement of dissolved oxygen. Thanks to OptiOxÀ, measuring dissolved oxygen is easier than ever before. For applications where the traditional polarographic measurement is preferred the S600-Kit is recommended. Optical oxygen measurement is superior to conventional technologies. OptiOxÀ is fast, precise and produces highly reproducible results. Because of the optical measuring principle used, the oxygen is not chemically consumed during the measurement, which makes stirring the sample superfluous. The InLab OptiOxÀ requires no polarization time, meaning you can start your measurement immediately. In addition, the whole measuring system has a high level of stability making calibration rarely necessary.
Supplied with:
S900-Kit:As S900-Basic but with InLabÂź OptiOx, guide to DO measurement and zero oxygen tablets.
Other types: S900-Basic: Includes instrument, DO/BOD expansion unit, 2 blank expansion units, uPlace electrode holder, semitransparent cover, operating instructions, installation and quick guide, LabXÂź direct pH PC software, declaration of conformity and test certificate.
Specifications
Measuring range (O2 Saturation)
InLabÂź OptiOx: 0.0 to 500 %
Resolution: 0.1
Measuring range (O2 concentration):
InLabÂź OptiOx: 0.000 to 50 mg/l (ppm)
Resolution: 0.001/0.01/0.1
Accuracy
InLabŸ OptiOx: ±0.1 mg/l from 0 to 8
±0.2 mg/l from 8 to 20
±10 % from 20 to 50
Measuring range (Pressure): 500 to 1100 mbar
Resolution: 1
Accuracy: ±2
Calibration points: 2
Sensor input:
InLabÂź OptiOx: MiniLTW (IP67)
Pressure compensation: automatic / manual
Type S900-Kit
Specifikationer
- FrÄgor om produkten, vÀnligen kontakta
- Jörgen Mattson, jm@buch-holm.se, +46 (0)40 305030
- Producent
- Mettler-Toledo
- Förpackning
- 1 st.
- Enhet i försÀljning
- EA
- UNSPSC